Section 03 · Auxiliary ventilation system
BPJ2 / QJZ
Intelligent auxiliary ventilation system for mines
Automatic ventilation control. Safety. Energy efficiency.
01 — Next-generation intelligent ventilation
Air where it is needed. In the volume that is needed.
The auxiliary ventilation system combines the fan, frequency converter, intelligent starter and mine atmosphere sensors into one controlled package. Fan output is set not by hand but by the actual air parameters in the heading.
The controller continuously reads the methane, airflow, air velocity and temperature sensors and changes the fan speed through the frequency converter. Power is backed up, and data goes to the dispatch monitoring system.
Safety
Automatic ventilation control based on methane concentration and other mine atmosphere parameters.
Energy efficiency
Fan output is adjusted to the actual air demand.
Reliability
Automatic changeover between main and standby equipment.
Digital control
Remote monitoring and the option of centralised control.
02 — System architecture
One system for intelligent ventilation control
- 1Auxiliary fan — delivers fresh air to the face through the duct.
- 2Frequency converter — changes the speed of the fan motor.
- 3Intelligent switch — switches between the two power feeds and changes over to standby.
- 4Main and standby supplies — two independent power lines.
- 5Mine atmosphere sensors — measure methane, airflow, air velocity and temperature.
- 6Industrial controller — processes the signals and issues control commands.
- 7Remote monitoring — reports equipment status to the control room.
03 — Automatic ventilation control
Intelligent control based on mine atmosphere parameters
The controller takes several parameters into account at once: methane concentration, airflow and air velocity, and air temperature. Fan output is set from all of these signals together, which keeps the required ventilation regime and reduces the risks of atmosphere parameters going out of range.
- 01Methane concentration changes
- 02Sensor signal received
- 03Controller processes the signal
- 04Fan speed changes
- 05Airflow is corrected
- Automatic fan speed control
- Methane concentration monitoring
- Regulation by airflow and air velocity
- Air temperature taken into account
- Automatic changeover between main and standby equipment
- Soft start of motors
- Fault monitoring
- Remote monitoring
Automatic speed control modes
Combined control — modes 3–5
- Mode 1 Methane Speed control by methane concentration
- Mode 2 Airflow Control by airflow
- Mode 3 Methane + airflow Main parameter: methane; additional: airflow
- Mode 4 Methane + airflow, velocity, t° Main parameter: methane; the others are additional
- Mode 5 Methane + velocity, t° Main parameter: methane; the others are additional
The system performs its built-in protective functions and helps reduce the risks of ventilation failures.
04 — QJZ intelligent starters
QJZ — intelligent control and power redundancy
Main parameters
| Series | QJZ |
| Supply voltage | 660/1140 V |
| Rated current | 2×160 A / 2×200 A |
| Frequency | 50 Hz |
| Duty | S1 |
| Utilisation category | AC-3 |
Functions
- Programmable logic controller
- Automatic power changeover
- LED and display indication
- Motor protection
- Fault diagnostics
Model comparison
| Model | Voltage, V | Rated current Ie, A | P max at 1140 V, kW | P max at 660 V, kW | Frequency |
|---|---|---|---|---|---|
| QJZ-2×160/1140(660)SF | 1140/660 | 2×160 | 237 | 138 | 50 Hz |
| QJZ-2×200/1140(660)SF | 1140/660 | 2×200 | 299 | 173 | 50 Hz |
05 — BPJ2 frequency converters
BPJ2 — precise control of fan output
- Rated power, kW
- 110 / 160
- Output frequency, Hz
- 5–50
- Supply voltage, V
- 660 / 1140
- Communication interfaces
- RS485 · Ethernet
| Cooling | air, heat-pipe |
| Duty | continuous |
Features
- SPWM frequency control
- Automatic output control
- Methane concentration monitoring
- Remote monitoring
- Motor protection functions
- Support for centralised control
Product range
| Model | Power | Input voltage | Input current | Carrier frequency | Dimensions, mm | Weight |
|---|---|---|---|---|---|---|
| BPJ2-160/1140SF | 160 kW | AC 1140 V | 104 A | 1.5 kHz | 2192×1121×1300 | 1680 kg |
| BPJ2-160/660SF | 160 kW | AC 660 V | 175 A | 2.5 kHz | 2192×1121×1300 | 1680 kg |
| BPJ2-110/1140SF | 110 kW | AC 1140 V | 73 A | 1.5 kHz | 1970×1300×1027 | 1500 kg |
| BPJ2-110/660SF | 110 kW | AC 660 V | 120 A | 2.5 kHz | 1970×1300×1027 | 1500 kg |
All models: output frequency 5–50 Hz, continuous duty, RS485 and Ethernet interfaces. BPJ2-160 is for a 150 kW fan or counter-rotating fans of 2×75 kW and below; BPJ2-110 is for a 110 kW fan or 2×55 kW and below.
06 — Reliability and industrial safety
A complete approach to mine ventilation safety
- 01 Methane control Fan output is regulated by sensor signals.
- 02 Redundancy Automatic changeover between main and standby equipment.
- 03 Motor protection Fault monitoring and protective functions of the control system.
- 04 Power interlocks Fan–power interlocks and methane-based power cut-off.
- 05 Dispatch monitoring Data is sent to the centralised monitoring system.
Intelligent ventilation — the basis of safe and efficient mine operation
- Safety
- Automation
- Energy efficiency
07 — Technical advice
Get technical advice
Describe the heading and the equipment: fan type and power, supply voltage, the control modes you need and the atmosphere parameters to monitor — we will put together a package with a BPJ2 converter and a QJZ starter.